AEROLEARN RWANDA/Aircraft General Knowledge/Chapter 13Search·My learning
Aircraft General Knowledge · Chapter 13

Pressurisation
and Oxygen

How aircraft protect occupants from low atmospheric pressure, maintain a safe cabin environment and provide supplementary oxygen when normal pressurisation is lost or physiological needs demand it.

ATPL-oriented study notesPressurisation systemsOxygen equipment12-question knowledge check

1. Introduction

Aircraft pressurisation maintains the pressure inside the occupied cabin at a level that allows people to function safely and comfortably while the aircraft operates in the thin atmosphere at altitude. The oxygen system provides a separate safety layer when cabin pressure is inadequate or when a specific task requires supplementary oxygen.

Supplementary oxygen is carried because pressurisation can fail, decompression can occur, and some operations may require oxygen even when the cabin remains pressurised. The type of oxygen equipment depends on the user and task: flight crew generally use a demand or pressure-demand regulator, while passenger systems may use continuous-flow gaseous oxygen or chemical oxygen generators.

Learning objectives

  • Explain why pressurisation is required and how hypoxia affects human performance.
  • Define cabin altitude, ambient pressure and cabin differential pressure.
  • Explain positive and negative differential pressure and the purpose of relief valves.
  • Describe the function of the outflow valve and the main types of pressure-control systems.
  • Interpret basic cabin climb, cruise and descent pressure schedules.
  • Explain decompression types, warnings and the role of supplementary oxygen.
  • Compare continuous-flow, diluter-demand and chemical oxygen systems.
  • Describe oxygen servicing precautions and the fire hazards associated with oxygen enrichment.

2. Atmosphere, oxygen and hypoxia

2.1 Why altitude affects breathing

Dry air contains approximately 21% oxygen by volume. The percentage does not suddenly decrease as an aircraft climbs; what decreases is the total atmospheric pressure and therefore the partial pressure of oxygen. With lower oxygen partial pressure, less oxygen moves from the lungs into the bloodstream during gas exchange.

At sea level, standard atmospheric pressure is approximately 101.3 kPa (14.7 psi). As altitude increases, atmospheric pressure falls. The body is exposed to a lower oxygen partial pressure even though the oxygen percentage in the surrounding air remains broadly the same.

Partial pressure of oxygen ≈ oxygen fraction × total atmospheric pressure

For a simplified dry-air example at sea level: \(0.21 × 14.7 \approx 3.1\) psi. At altitude, the total pressure falls and the oxygen partial pressure falls with it. This is the central physiological reason high-altitude flight requires pressurisation or supplemental oxygen.

2.2 Cabin altitude

Cabin altitude is the altitude in the standard atmosphere that corresponds to the pressure measured inside the cabin. It is not the aircraft's geometric height. If an aircraft is flying at 35,000 ft while its cabin is maintained at an equivalent pressure altitude of 6,000 ft, the occupants experience a cabin pressure corresponding approximately to 6,000 ft, not 35,000 ft.

The FAA Pilot's Handbook includes a labelled high-performance aircraft pressurisation schematic and a standard-atmosphere pressure chart. Open the handbook and review Chapter 7, Aircraft Systems.

2.3 Hypoxia

Hypoxia is a condition in which body tissues do not receive enough oxygen to function normally. In aviation, hypoxia is particularly dangerous because it can impair judgement, memory, coordination and decision-making before the affected person recognises that anything is wrong.

TypeBasic mechanismAviation example
HypoxicInsufficient oxygen partial pressure in the lungs/blood.High cabin altitude or unpressurised flight at excessive altitude.
HypemicBlood cannot carry its normal oxygen load.Carbon monoxide exposure reduces effective oxygen-carrying capacity.
StagnantBlood flow is insufficient to deliver oxygen to tissues.Circulatory problems or severe acceleration effects.
HistotoxicCells cannot use delivered oxygen effectively.Certain toxic exposures.

2.4 Symptoms and performance effects

Symptoms vary between individuals and are affected by altitude, duration of exposure, workload, fatigue, illness, smoking and other factors. Possible effects include euphoria, impaired judgement, headache, dizziness, visual disturbance, poor coordination, slowed thinking and eventual loss of consciousness.

Operational warning: hypoxia can reduce a pilot's ability to recognise and correct the problem. Do not rely on symptoms as the primary warning. Follow the aircraft's oxygen-use requirements and emergency procedures.

2.5 Time of useful consciousness

Time of useful consciousness (TUC) is the approximate period during which a person can perform purposeful actions after oxygen becomes inadequate. It is not a guaranteed time to unconsciousness and varies considerably. Rapid decompression can shorten the useful period because expanding lung gas is expelled and oxygen partial pressure falls abruptly.

At very high flight altitudes, the available time may be extremely short. This is why crew oxygen masks are designed for rapid donning and why immediate action is emphasised in high-altitude operations.

3. Cabin pressure fundamentals

3.1 How the cabin is pressurised

Conditioned air from the ECS enters the pressure vessel through supply ducts. The cabin is not sealed: air leaves through the outflow valve and through designed leakage paths. Cabin pressure is determined by the relationship between the mass of air entering and the mass of air leaving.

Conditioned air enters cabin→Cabin pressure builds→Outflow valve meters discharged air→Cabin pressure follows selected schedule

If inflow exceeds outflow, cabin pressure tends to increase and cabin altitude decreases. If outflow exceeds inflow, cabin pressure tends to decrease and cabin altitude increases. At a stable cabin pressure, inflow and outflow are approximately balanced.

3.2 Cabin altitude schedule

Many transport aircraft are designed to maintain a cabin altitude around 6,000–8,000 ft during high-altitude cruise, although the actual schedule depends on aircraft type, aircraft altitude, selected landing altitude and differential-pressure limits. Some newer designs achieve lower cabin altitudes in cruise. These figures are descriptive examples, not a universal limit or a substitute for aircraft-specific data.

During climb, the cabin is allowed to climb at a controlled rate rather than immediately following the aircraft. During cruise, the cabin altitude may be held approximately constant until the structural differential-pressure limit is approached. During descent, the system increases cabin pressure gradually so that the cabin reaches the planned landing pressure near touchdown.

3.3 Cabin altitude versus aircraft altitude

TermMeaning
Aircraft altitudeThe aircraft's altitude above the reference datum, normally indicated altitude in the context of flight operations.
Ambient pressureAtmospheric pressure outside the aircraft at its current altitude.
Cabin pressureThe absolute pressure maintained inside the pressurised compartment.
Cabin altitudeStandard-atmosphere altitude equivalent to the measured cabin pressure.
Differential pressure (ΔP)Cabin absolute pressure minus outside ambient absolute pressure.

4. Differential pressure and aircraft structure

4.1 Positive differential pressure

During normal high-altitude flight, cabin pressure is higher than outside atmospheric pressure. This is positive differential pressure. The fuselage acts as a pressure vessel and must withstand the outward load created by the pressure difference across its skin, doors, windows, bulkheads and joints.

ΔP = cabin absolute pressure − outside ambient absolute pressure

For example, if cabin pressure is 10.9 psi and outside pressure is 4.8 psi, the differential is 6.1 psi. The figures are illustrative and are not a limit for any particular aircraft.

4.2 Maximum differential pressure

Every pressurised aircraft has a maximum permitted differential pressure determined by its structural design and certification. At high altitude, the controller may no longer be able to maintain the originally selected cabin altitude without exceeding that limit. It then allows cabin altitude to rise while keeping the differential within the approved maximum.

Maximum differential pressure is an aircraft limitation, not a target that should be exceeded. The AFM/POH or FCOM gives the applicable value and operating procedures.

4.3 Negative differential pressure

Negative differential pressure occurs when outside ambient pressure becomes greater than cabin pressure. This can happen during a rapid descent, rapid external pressure increase or certain abnormal conditions. The pressure vessel is designed primarily to withstand cabin pressure pushing outward; it is not necessarily designed to withstand a large inward crushing load.

Negative-pressure relief valves allow outside air to enter the cabin when the pressure difference becomes excessive, protecting the structure.

4.4 Structural considerations

  • Fuselage skin and frames carry repeated pressurisation loads during every flight cycle.
  • Doors and hatches require pressure-locking features so they cannot open under an unsafe pressure differential.
  • Windows are designed to withstand pressure and thermal loads, with inspection requirements for damage and crazing.
  • Fatigue and corrosion can affect pressure-vessel integrity over time.
  • Pressure-control and relief systems must protect the aircraft if normal control fails.

5. Relief valves and safety devices

5.1 Positive-pressure safety valves

Positive-pressure relief valves protect the fuselage from excessive cabin-to-ambient differential pressure. They are independent protective devices and are not intended to replace normal pressure control. If the cabin differential rises above the valve's designed relief setting, the valve opens and vents cabin air overboard to reduce the pressure difference.

5.2 Negative-pressure relief valves

Negative-pressure relief valves open when outside pressure exceeds cabin pressure by the designed threshold. They admit ambient air into the cabin, reducing the inward differential. The valve may be a spring-loaded flap, poppet or another type of pressure-operated device.

5.3 Inward and outward relief: compare

DevicePressure conditionFlow directionPurpose
Positive-pressure safety valveCabin pressure excessively higher than ambient.Cabin → outsidePrevents excessive outward structural loading.
Negative-pressure relief valveOutside pressure excessively higher than cabin.Outside → cabinPrevents excessive inward structural loading.

5.4 Inward relief and door protection

Some aircraft incorporate pressure equalisation features in doors or other structural areas. The aim is to prevent a large pressure difference from acting in a direction for which the structure is not designed. Pressure-locking systems also prevent doors from being opened while an unsafe differential remains.

Exam memory: positive differential means cabin pressure is greater — relieve air outward. Negative differential means outside pressure is greater — admit air inward.

6. Cabin pressure control systems

6.1 The outflow valve

The outflow valve is the principal modulating component in many cabin pressure-control systems. It controls how much cabin air is discharged. Opening the valve further increases outflow and tends to increase cabin altitude. Closing it reduces outflow and tends to decrease cabin altitude, assuming adequate inflow.

Pressurised cabin with outflow valve, safety relief and negative relief valves
The main parts of a pressurisation system: air comes in from the packs, the outflow valve controls how much leaves, and relief valves protect the structure. Diagram: AeroLearn Rwanda
ECS / packsconditioned airPressurised cabinCabin pressure is controlled bybalancing inflow and outflowOutflowvalveTo atmosphereSimplified system concept — actual valve position and control logic are aircraft-specific.

6.2 Other system components

ComponentFunction
Cabin pressure controllerCalculates the required cabin pressure schedule and commands the outflow valve.
Cabin pressure selectorAllows the crew to enter or confirm flight altitude and landing field elevation, depending on system design.
Cabin pressure sensorMeasures cabin pressure for the controller and flight deck indications.
Ambient/static pressure sourceProvides outside pressure information for differential and schedule calculations.
Outflow valve actuatorMoves the valve in response to controller commands or manual control.
Safety valvesProvide independent positive and/or negative pressure relief.
Dump valveProvides a means of rapidly opening the outflow path when required by the approved design and procedure.

6.3 Pneumatic pressure-control systems

Older systems may use pneumatic pressure sensing and control. Cabin and ambient pressure act on diaphragms, bellows and capsules. Springs and restricted orifices establish reference forces and time delays. The controller modulates the discharge valve without requiring a fully electronic control loop.

A pneumatic controller may contain an isobaric capsule, a differential-pressure capsule and a rate-control mechanism. The isobaric element maintains a selected cabin pressure altitude while it is within its operating range. When the aircraft climbs high enough that the maximum differential is reached, the differential capsule takes over and allows cabin altitude to increase while limiting ΔP.

6.4 Electro-pneumatic systems

Electro-pneumatic systems use electrical signals and sensors to control pneumatic or electrically actuated valves. The controller may use pressure transducers, altitude data and crew selections to position the outflow valve. Electrical power loss or controller failure may require transfer to a standby or manual mode, depending on the aircraft.

6.5 Electronic pressure-control systems

Modern systems commonly use digital controllers that receive inputs from air-data systems, cabin pressure sensors, landing-field altitude selections and aircraft configuration signals. The controller calculates a cabin pressure schedule and commands an electrically driven outflow valve actuator. Redundant controllers or channels may provide automatic changeover if a fault is detected.

Electronic systems can account for aircraft altitude, vertical speed, landing elevation and other flight data. The aim is to achieve a smooth cabin profile while respecting pressure differential, cabin rate and structural limits.

6.6 Automatic, standby and manual modes

  • Automatic: the controller positions the outflow valve to follow the programmed schedule.
  • Standby / alternate: a redundant controller or channel may take over after a fault.
  • Manual: the crew commands the outflow valve directly, following the aircraft's procedure and monitoring the cabin indications.
Important: manual pressurisation control requires careful monitoring. The direction of switch movement and the relationship between valve position and cabin altitude must be learned from the aircraft type's FCOM/AFM. Never assume that all aircraft use the same control logic.

7. Cabin pressure profiles: climb, cruise and descent

7.1 Before take-off and initial pressurisation

On the ground, cabin pressure is normally close to ambient pressure. Depending on aircraft design, the controller may establish a small initial cabin pressure change after take-off to confirm that the pressure vessel is responding and to avoid abrupt pressure changes. The exact initial schedule is type-specific.

Graph of aircraft altitude and cabin altitude during climb, cruise and descent
A typical pressurisation profile: the cabin altitude changes slowly and stays below about 8,000 ft while the aircraft climbs to cruise altitude. Diagram: AeroLearn Rwanda

7.2 Climb

As the aircraft climbs, outside pressure decreases. The cabin controller allows cabin pressure to decrease gradually, so cabin altitude rises at a controlled rate. If cabin pressure were held at sea-level pressure while the aircraft continued climbing, the differential pressure would eventually exceed the structural limit.

7.3 Isobaric control

In the isobaric phase, the controller maintains a selected cabin pressure altitude. The aircraft can continue climbing while the cabin remains approximately at the selected cabin altitude, so differential pressure increases as outside pressure falls.

7.4 Maximum differential-pressure control

When the aircraft reaches the point where maintaining the selected cabin altitude would exceed the maximum differential, the controller changes to a differential-pressure-limited schedule. The cabin altitude is then allowed to rise with aircraft altitude so that the maximum ΔP is not exceeded.

Time through flightAltitude (conceptual)Aircraft altitudeCabin altitude scheduleClimbCruiseDescentConceptual only — not to scale and not a type-specific operating profile.

7.5 Descent

7.6 Cabin pressure bumping

Pressure bumping describes unwanted repeated changes in cabin pressure, often associated with a controller repeatedly adjusting the outflow valve near a pressure limit or during small aircraft altitude variations. It can cause passenger discomfort. Modern control laws and operating margins are designed to reduce hunting and unnecessary valve movement.

7.7 Go-around

During a go-around, the aircraft climbs again after the cabin has been scheduled for descent. The pressurisation controller must transition to the new flight profile. Automatic systems normally use aircraft and flight-management data; older or manually selected systems may require crew action according to the aircraft procedure.

7.8 Dump valve

A dump function opens the outflow path to rapidly reduce cabin pressure when required by the aircraft design or ground/maintenance procedure. It is not a normal substitute for automatic pressure control. The crew must use it only as directed by the applicable checklist.

7.9 Ditching considerations

Some aircraft have a ditching configuration that closes or changes selected external openings to reduce water ingress. The pressurisation and ventilation response is aircraft-specific. Do not assume that selecting a ditching switch simply closes every valve or that it creates a watertight pressure vessel.

8. Controllers, warnings and indications

8.1 What the flight crew monitors

  • Cabin altitude: pressure altitude inside the cabin.
  • Cabin rate: rate at which cabin altitude is changing.
  • Differential pressure: pressure difference between cabin and ambient.
  • Outflow valve position: indication of the valve's commanded or measured position.
  • Cabin altitude warning: alerts the crew when cabin altitude reaches the aircraft's warning threshold.
  • System status / fault messages: identify controller, sensor, valve or mode abnormalities where provided.

8.2 Cabin altitude warning

Pressurised aircraft are fitted with warning systems to alert the crew to an unsafe cabin altitude. Aural and visual warnings are used according to the aircraft's certification and system design. The warning threshold and alert logic must be checked in the applicable aircraft documentation.

8.3 Pressure controller failure

A failure may cause the system to revert to a standby controller, manual mode or another designed fallback. The crew must recognise the mode annunciation, confirm the cabin pressure indications and apply the QRH/FCOM procedure. A controller fault does not automatically mean that the pressure vessel has decompressed; it means the crew must determine whether pressure control remains effective.

9. Leakage and decompression

9.1 Leakage and sealing

A pressurised fuselage is not perfectly airtight. Designed ventilation and outflow paths are controlled, while seals around doors, windows, access panels, cables and control penetrations limit unintended leakage. Excessive leakage can reduce the system's ability to maintain cabin pressure, particularly at high altitude when the pressure differential is large.

9.2 Slow decompression

Slow decompression is a gradual loss of cabin pressure. It may result from a leak, a valve that remains too far open, reduced air supply or a system malfunction. Because the change may be subtle, the cabin altitude warning and instrument indications are important. Crew members should not rely solely on whether passengers appear comfortable.

9.3 Rapid decompression

Rapid decompression is a sudden loss of cabin pressure over a short period. It may be associated with a structural failure, door/window failure or major system event. Common signs include a loud noise, rushing air, flying debris, fog-like mist caused by rapid cooling and expansion, and a sudden change in cabin conditions.

9.4 Explosive decompression

Explosive decompression is an extremely rapid pressure loss associated with a major structural opening or failure. The pressure equalisation can occur in seconds. The physiological consequences can be severe, and the immediate threat at high altitude is hypoxia.

TypeTypical characteristicOperational concern
SlowPressure loss develops gradually.May be difficult to notice without monitoring; cabin altitude can rise progressively.
RapidPressure loss occurs over a short interval.Noise, fog, airflow and sudden hypoxia risk; immediate emergency response required.
ExplosiveExtremely rapid equalisation, often due to major structural failure.Very short useful time for action; structural and physiological hazards.

9.5 Emergency descent and oxygen

Following a pressurisation failure at altitude, the aircraft may need to descend to an altitude where supplemental oxygen is no longer required or where the occupants can be supported by the available oxygen system. The emergency descent profile must respect terrain clearance, aircraft limitations, traffic and the approved checklist. Crew oxygen must be used immediately as directed by the procedure.

Critical operational principle: in a suspected high-altitude decompression, don the flight crew oxygen mask and establish oxygen supply in accordance with the aircraft checklist before attempting prolonged diagnosis or troubleshooting. The exact memory items and sequence are aircraft-specific.

9.6 Automatic passenger mask deployment

Many transport aircraft have passenger oxygen masks that deploy automatically when cabin altitude reaches a designed threshold. The threshold and deployment logic differ by aircraft and certification basis. Some systems also provide a flight-deck manual deployment control. Deployment does not necessarily mean the aircraft has reached its maximum emergency cabin altitude; it is intended to make oxygen available in time.

10. Aircraft oxygen systems

10.1 Oxygen storage and supply forms

System typeTypical useKey feature
Compressed gaseous oxygenFlight crew, portable sets and some passenger installations.Stored under high pressure and reduced through regulators.
Chemical oxygen generatorPassenger emergency oxygen on many transport aircraft.Produces oxygen after activation; generally a one-use device.
Liquid oxygen (LOX)Selected specialist/military installations.High storage density but demanding handling and servicing requirements.

10.2 Continuous-flow oxygen

A continuous-flow system supplies oxygen at a regulated flow rate regardless of the user's exact inhalation phase. A pressure regulator reduces cylinder pressure to a lower delivery pressure, and a calibrated orifice or flow device meters the supply to the mask. An exhalation valve allows exhaled air to leave the mask.

Continuous-flow systems are relatively simple and may be used in light aircraft or as passenger supplementary oxygen. Because oxygen flows continuously, some is delivered during exhalation and may be wasted. The system's adequacy depends on altitude, flow rate, mask fit and the approved equipment limitations.

10.3 Diluter-demand oxygen

A diluter-demand regulator supplies oxygen when the user inhales. At lower cabin altitudes, it can mix oxygen with cabin ambient air to conserve the stored oxygen while providing the required mixture. As cabin altitude increases, a barometric mechanism reduces or closes the ambient-air contribution so that the delivered mixture becomes richer in oxygen.

The regulator typically uses a diaphragm responsive to the pressure difference created during inhalation. Inhalation moves the diaphragm and opens the demand valve; when inhalation stops, the valve closes. This is more efficient than a simple continuous-flow system for flight crew use.

10.4 Pressure-demand oxygen

At very high altitudes, oxygen may need to be delivered under positive pressure to help overcome the low ambient pressure. Pressure-demand regulators provide oxygen at a pressure above the surrounding cabin pressure according to the regulator schedule. This supports adequate oxygen delivery when normal demand or diluter-demand operation is insufficient.

10.5 Oxygen flow indication

Because oxygen is colourless and odourless, crew systems may include a flow indicator or “blinker” that provides a visual indication of flow. The indicator's movement or appearance must be interpreted according to its design. A flow indication does not, by itself, prove that the mask fits correctly or that the user is receiving the intended oxygen concentration.

11. Flight crew oxygen

11.1 Crew mask and regulator

Flight crew oxygen masks are designed for rapid access and donning. A typical installation includes a stowage box, mask assembly, regulator, supply hose, microphone and communication connections, harness inflation or adjustment mechanism, and a flow indicator. The mask may be connected to a diluter-demand or pressure-demand regulator.

11.2 Regulator selector modes

ModeGeneral purposeImportant distinction
NORMAL / DILUTERSupplies an oxygen-air mixture, with the ratio adjusted according to cabin altitude.Ambient cabin air may enter the regulator if the design permits.
100% OXYGENCloses or reduces the ambient-air dilution path and supplies undiluted oxygen.Useful when smoke/fumes contamination is suspected, if specified by the aircraft procedure.
EMERGENCY / PRESSUREProvides a higher flow or positive-pressure supply according to regulator design.Designed for specified emergency conditions; not interchangeable with every regulator's test mode.
TESTChecks regulator operation or purges the line as designed.Must not be used for breathing unless the manufacturer's procedure explicitly permits it.

11.3 Diluter-demand operation

  1. Oxygen from the storage cylinder passes through high-pressure lines and pressure-reduction stages.
  2. The regulator receives the selected oxygen supply.
  3. When the pilot inhales, a pressure change moves the diaphragm.
  4. The demand valve opens and meters oxygen to the mask.
  5. As inhalation ends, the diaphragm returns and the valve closes.
  6. At higher cabin altitude, the regulator progressively reduces dilution with ambient air.

11.4 Smoke and fumes

If the ventilation air is contaminated with smoke or fumes, a diluter-demand mask left in a mode that admits cabin air could allow contaminated air to enter the mask. Many crew regulators therefore provide a 100% oxygen selection that isolates the dilution-air path. The exact mode and procedure must be confirmed from the aircraft's QRH/FCOM.

Mask test caution: some regulator test settings deliver a pressure or flow intended only for checking the system. Incorrect use can cause injury. Follow the aircraft and equipment manufacturer's instructions; do not experiment with regulator settings.

12. Passenger oxygen systems

12.1 Passenger service units (PSUs)

Passenger masks are commonly stowed in overhead service units above passenger seats and in selected lavatory or cabin-crew locations. A PSU may contain several masks so that each seating position has access to a mask, with additional masks provided for crew or other occupants as required by the applicable certification basis.

12.2 Automatic deployment

A barometric switch or electronic control system detects when cabin altitude reaches the deployment threshold. It releases the PSU door so that the masks drop into view, often in a half-hung position. The passenger normally pulls a mask down to start oxygen flow or activate the generator, depending on system design.

12.3 Continuous-flow passenger system

12.4 Chemical oxygen generators

A chemical generator contains a solid chemical charge, often called an oxygen candle. When activated, a chemical reaction releases oxygen. The generator is designed to provide oxygen for a specified period; once activated, it generally cannot be switched off and reused.

The generator can become hot during operation. It is installed with thermal insulation and designed airflow/ducting to keep the delivered oxygen within specified limits. A pressure-relief feature protects against excessive internal pressure. A heat-sensitive indicator may show whether a unit has been activated.

12.5 Activation and one-shot operation

In some installations, pulling a mask operates a lanyard or electrical initiator that starts the chemical reaction. When one generator supplies several masks, pulling any one of the connected masks may activate the common generator for all masks on that unit. Once started, the reaction continues until the chemical charge is consumed.

Handling caution: an activated chemical oxygen generator can become very hot and must be treated as a fire/burn hazard. Do not handle, disconnect or stow an activated unit except under the approved emergency or maintenance procedure.

12.6 Passenger mask limitations in smoke

Passenger emergency masks are generally designed to supply supplementary oxygen while allowing the user to breathe some surrounding cabin air. They are not protective breathing equipment and are not designed to protect against smoke or toxic fumes. A smoke-filled cabin requires the aircraft's specific crew procedures and appropriate protective breathing equipment.

13. Protective breathing equipment, portable and first-aid oxygen

13.1 Protective breathing equipment (PBE)

PBE is not the same as a passenger oxygen mask. The protective hood or mask is designed to protect the eyes and respiratory tract and provide a breathing supply for the equipment's rated duration. Users must follow training, donning instructions, operating limitations and expiry/inspection requirements.

13.2 Portable oxygen equipment

Portable oxygen sets generally include a cylinder, pressure gauge, pressure-reducing/flow-control assembly, hose, mask or cannula and carrying case. They may be used for first aid or other approved purposes. The quantity available depends on cylinder size, pressure, flow setting and equipment condition.

13.3 First-aid oxygen

First-aid oxygen is intended to support a person who requires supplementary oxygen, subject to crew training and the operator's procedures. It is not a substitute for medical assessment, and it should not be confused with the emergency oxygen system intended for decompression.

13.4 Cabin crew oxygen

Cabin crew need access to supplementary oxygen when away from their seats. Additional masks or oxygen outlets may be located near crew stations, galleys or other work areas. The location and availability of these outlets depend on the aircraft's approved layout.

14. Oxygen servicing and fire safety

14.1 Oxygen storage pressure and gauges

Gaseous oxygen is stored at high pressure in dedicated cylinders. Flight deck indications may show cylinder pressure or a calculated quantity. Pressure is affected by temperature: a cylinder's indicated pressure changes as the gas warms or cools. A pressure gauge is therefore not a direct linear measure of the amount of oxygen remaining under all temperature conditions.

14.2 Replenishing oxygen systems

Oxygen charging is a specialised maintenance task. The charging rate must be controlled because rapid compression heats the gas and cylinder. A temporarily elevated temperature can produce a misleading pressure reading. The system must be charged using approved equipment, procedures and pressure/temperature corrections.

14.3 Cleanliness and contamination

Oxygen systems must be kept clean and free from oil, grease, dirt, moisture and incompatible materials. Contamination can create serious ignition hazards in high-pressure oxygen. Charging hoses and connectors must be suitable for oxygen service and handled according to the maintenance instructions.

14.4 Oxygen and fire

Oxygen is not itself a fuel, but it supports combustion. In an oxygen-enriched atmosphere, materials can ignite more readily and burn more intensely. Oils and greases that are relatively stable in normal air can become extremely hazardous in high-pressure oxygen systems.

Oxygen safety rule: never apply oil, grease or non-approved lubricants to oxygen fittings, regulators, valves or charging equipment. Use only approved oxygen-compatible materials and maintenance procedures.

14.5 Thermal compensators and pressure/temperature corrections

Some oxygen charging arrangements include a thermal compensator or use a pressure-versus-temperature chart. The aim is to obtain an accurate cylinder charge after the gas has returned to a stable temperature. A hot cylinder may show a higher pressure than it will show after cooling.

14.6 Inspection and servicing principles

  • Check cylinder identification, serviceability and inspection status.
  • Ensure caps, blanks and protective covers are fitted when required.
  • Keep connectors and hoses clean and protected against contamination.
  • Use approved charging carts, pressure regulators and adapters.
  • Charge slowly and monitor pressure and temperature in accordance with the maintenance manual.
  • Leak-test and function-test the system using approved procedures.

15. Advanced engineering: pressure vessel, sensing and valve operation

15.1 The pressure vessel as a structural system

The pressurised portion of an aircraft is a pressure vessel formed by the fuselage skin, frames, stringers, floor structure, pressure bulkheads, doors, windows and their seals. Internal pressure acts in all directions. The curved fuselage shell carries much of the load as membrane stress, while frames and stringers help preserve shape and distribute local loads. Door and window cut-outs interrupt the shell and therefore require reinforced surrounding structure.

Every flight cycle normally includes a pressurisation and depressurisation cycle. Over many cycles, repeated stress can initiate fatigue cracks, particularly around joints, fasteners, window corners, door frames and areas affected by corrosion or damage. This is why pressure-vessel inspections, structural repair limits and fatigue-life controls are essential parts of continuing airworthiness.

Engineering distinction: cabin differential pressure is a load applied to the pressure vessel. Cabin altitude is a pressure-equivalent indication. They are related, but they are not interchangeable quantities.

15.2 Hoop stress and longitudinal stress — simplified model

For a thin-walled cylindrical pressure vessel, the simplified membrane-stress relationships help explain why fuselage structure is designed around pressure differential. The idealised model assumes a thin uniform wall, a circular cylinder and uniform pressure; an aircraft fuselage has windows, doors, joints, changing cross-sections and local reinforcements, so actual design analysis is much more complex.

Hoop stress: σh ≈ (ΔP × r) / t
Longitudinal stress: σl ≈ (ΔP × r) / (2t)

Where ΔP is internal-to-external pressure difference, r is the idealised fuselage radius and t is wall thickness. The simplified cylinder model predicts hoop stress about twice the longitudinal stress. This is a conceptual engineering relationship, not a method for calculating aircraft structural limits.

15.3 How a modulating outflow valve works

The outflow valve is not simply an open/closed drain. In normal operation it is positioned progressively to control the rate of cabin air discharge. Depending on design, an electric motor, pneumatic actuator or electropneumatic control element moves the valve. A controller compares the measured cabin pressure and scheduled target, then commands the valve to correct the difference.

Typical control response

  • If cabin altitude is higher than the scheduled target, the controller generally reduces outflow by moving the valve toward closed, allowing cabin pressure to increase.
  • If cabin altitude is lower than the scheduled target, the controller generally increases outflow by moving the valve toward open, allowing cabin pressure to decrease.
  • If differential pressure approaches its limit, the schedule prioritises structural protection and allows cabin altitude to rise as necessary.
  • If a pressure sensor, actuator or controller fails, the system may change to a standby channel or manual mode, depending on aircraft design.

15.4 Pressure sensing and static sources

The controller needs reliable information about cabin pressure and outside ambient pressure. Cabin pressure is sensed from the pressure vessel, while ambient pressure is obtained from a suitable static-pressure source or air-data input. The controller may also receive aircraft altitude, vertical speed, landing elevation, weight-on-wheels and flight-management-system data.

Incorrect sensing can produce incorrect control commands. A blocked, leaking or mis-routed sensing line can make the controller believe the cabin pressure is different from its true value. For that reason, sensing lines, pressure ports, transducers and connectors are important maintenance inspection items.

15.5 Controller logic: isobaric and differential modes

In isobaric control, the system attempts to maintain a selected cabin pressure altitude. In differential control, it limits the pressure difference between the cabin and outside atmosphere. The transition point depends on the selected cabin altitude, aircraft altitude and maximum differential limit.

Think of the controller as having two priorities: maintain the selected cabin pressure when structurally possible, then protect the pressure vessel when the maximum permitted differential is reached. The controller does not have authority to exceed the aircraft's structural limit merely to preserve passenger comfort.

15.6 Pressure-relief valve construction and function

A positive-pressure relief valve may use a spring-loaded poppet or diaphragm arrangement. Under normal conditions, spring force and the pressure balance keep the valve seated. When the cabin-to-ambient differential exceeds the designed threshold, the force balance changes and the valve opens to discharge cabin air. A negative-pressure relief valve operates in the opposite direction, admitting outside air when ambient pressure is sufficiently greater than cabin pressure.

FAA AC 65-15A explains pressurisation valves, pneumatic outflow valves, pressure relief and negative-pressure relief. Consult the relevant pressurisation section for additional technical detail.

Open FAA AC 65-15A — Airframe Handbook (PDF)

15.7 Pressure leakage paths

Unintended leakage may occur around door seals, window seals, access panels, pressure bulkhead penetrations, wiring and control runs, drain masts or damaged structure. A small leak may be manageable at lower altitude but become significant at high altitude when the pressure differential is larger. The controller may compensate by closing the outflow valve further; if the available inflow and valve authority are insufficient, cabin altitude will rise.

Exam trap: a fully or nearly fully closed outflow valve does not prove that cabin pressure is safe. The system may still be unable to maintain pressure because of inadequate inflow, excessive leakage or a sensing/control fault.

16. Advanced oxygen-system operation and component detail

16.1 Oxygen system architecture

A typical gaseous oxygen installation contains a storage cylinder, cylinder shut-off valve, charging connection, pressure gauge or transducer, pressure-reducing regulator, distribution lines, user control valves and dispensing equipment. Some systems have an intermediate pressure stage followed by local regulators at the crew stations. Relief devices protect lines and components from excessive pressure if a regulator fails.

Storage cylinder→Shut-off / pressure reduction→Distribution manifold→Local regulator→Mask / outlet

16.2 High-pressure and low-pressure sides

The high-pressure side carries oxygen from the cylinder to the pressure-reduction stage. The low-pressure side carries regulated oxygen toward the mask or outlet. Components on the high-pressure side must be designed for the cylinder pressure and oxygen compatibility. A leak or failure upstream of the regulator can release oxygen at a much higher rate than a downstream low-pressure leak.

16.3 Pressure reduction and flow regulation

Pressure reduction lowers the cylinder pressure to a level suitable for distribution. Flow regulation then controls how much oxygen reaches the user. These are different functions: a pressure regulator controls pressure, while a metering device or demand valve controls flow according to the system design and user demand.

16.4 Demand regulator operation — component sequence

  1. The crew selects the required operating mode and confirms the supply is available.
  2. During inhalation, pressure in the mask changes relative to the regulator reference pressure.
  3. The diaphragm responds to this pressure difference and moves the demand mechanism.
  4. The demand valve opens and oxygen flows toward the mask.
  5. When inhalation stops, the diaphragm returns and the valve closes or reduces flow.
  6. The altitude-sensing element adjusts the air/oxygen ratio as cabin altitude changes.

16.5 The aneroid / barometric element

16.6 Continuous-flow system: strengths and limitations

Continuous-flow equipment is mechanically straightforward and can be appropriate for light aircraft and passenger installations. However, the flow is not matched to each inhalation in the same way as a demand regulator. Oxygen can be wasted during exhalation, and the effective oxygen concentration depends on the flow rate, mask fit, breathing pattern and altitude. The approved equipment's altitude and duration limits must be observed.

16.7 Chemical oxygen generator — chemistry and thermal management

A chemical generator uses a solid chemical charge that releases oxygen when initiated. A common aviation design uses a sodium-chlorate-based oxygen candle with a fuel component that supports the reaction. The generator contains a charge, ignition mechanism, filter, thermal insulation, outlet and associated mask tubing. The precise chemistry and construction vary by manufacturer.

The reaction is exothermic: heat is released as oxygen is produced. The generator's casing, thermal insulation, outlet path and tubing are designed to manage heat and deliver the gas to the masks. The oxygen may pass through a cooling path and reservoir bag before reaching the user. A pressure-relief feature protects the generator if internal pressure rises above its designed limit.

Do not confuse the generator with a compressed oxygen cylinder. The chemical unit does not store a reusable charge of compressed oxygen. It produces oxygen after activation and normally continues reacting until its charge is exhausted.

16.8 Passenger mask deployment versus oxygen activation

Two separate events may occur: the PSU door releases and the masks become visible; then a mask is pulled and the oxygen supply is activated. On chemical-generator installations, pulling one mask may initiate a generator shared by several masks. On gaseous installations, pulling the mask may open a valve from the manifold. The exact mechanism is aircraft-specific.

16.9 PBE compared with supplementary oxygen masks

FeaturePassenger oxygen maskFlight crew oxygen maskPBE / smoke hood
Primary purposeSupplementary oxygen during cabin depressurisation.Breathing oxygen for crew, including emergency use.Protects eyes and respiratory tract from smoke/fumes while providing breathing supply.
Smoke protectionNot designed for smoke protection.Depends on mask seal and regulator mode; use prescribed procedure.Designed for the specified protective duration and conditions.
Typical activationPull-down mask / automatic supply release.Crew dons mask and selects system mode.Donning and activation sequence depends on equipment type.
DurationDepends on generator or system supply.Depends on cylinder quantity, flow and regulator.Limited rated duration; check unit markings and manuals.

16.10 Oxygen quantity and pressure are not identical

A cylinder pressure indication is affected by temperature. For a fixed-volume cylinder containing a fixed mass of gas, pressure changes with absolute temperature. This is why a pressure reading taken immediately after a rapid charge may be higher than the stabilised reading after the cylinder cools. A gauge showing half the full pressure does not necessarily mean exactly half the usable oxygen quantity under every operating condition.

17. Decompression recognition and crew response principles

17.1 Physiological and environmental cues

Decompression cues can include a loud bang or rushing-air sound, sudden cold, mist or fog from water vapour condensing as air expands and cools, loose objects moving, ear discomfort, breathing difficulty and oxygen masks deploying. Slow decompression may produce few obvious cabin cues; pressure indications and warnings remain essential.

17.2 Why the cabin may fog

Cabin air contains water vapour. When pressure falls rapidly, the air expands and cools. If the temperature falls below the dew point, some water vapour condenses into tiny droplets, creating a visible mist. This mist is not necessarily smoke, although the crew must assess any smoke/fume indication carefully and follow the checklist.

17.3 Physiological effects of rapid decompression

When cabin pressure drops, gases in body cavities expand. The lungs normally vent air through the airway, while the middle ear and sinuses may experience pressure differences if passages are blocked. The most serious operational threat at altitude is hypoxia. Rapid decompression can shorten time of useful consciousness compared with a gradual exposure because the oxygen partial pressure falls abruptly.

17.4 Immediate action priorities

The general priorities are: protect the flight crew's ability to function, establish the required oxygen supply, control the aircraft, initiate the appropriate descent, and then complete the remaining checklist and communications. This is a conceptual framework only; the exact memory items and order must come from the aircraft's approved QRH/FCOM.

Recognise decompression→Don crew oxygen / establish supply→Control aircraft and initiate approved descent→Complete checklist and assess cabin

17.5 Emergency descent considerations

An emergency descent must account for terrain and minimum safe altitude, airspeed limits, aircraft configuration, engine limitations, traffic, weather, passenger and cabin-crew needs, and ATC coordination when time permits. The descent target is determined by terrain clearance and the aircraft's approved procedures, not by a single universal altitude.

17.6 Passenger oxygen and descent planning

Passenger oxygen systems are designed to provide a limited supply that supports occupants during the time needed to descend to a safer altitude. The required duration and number of dispensers depend on the applicable certification and operating rules. Operators must ensure the system is maintained and the flight crew understands its deployment logic and limitations.

Training boundary: do not memorise generic warning thresholds as if they apply to every aircraft. Learn the specific warning altitude, automatic valve logic, mask deployment threshold, oxygen duration and emergency descent procedure from the aircraft's approved documents.

18. Worked operational examples

Example 1 — Calculate cabin differential pressure

Given: cabin pressure is 10.9 psi and outside ambient pressure is 4.8 psi.

Interpretation: cabin pressure is 6.1 psi higher than ambient pressure. Compare this value with the aircraft's approved maximum differential pressure; do not assume 6.1 psi is a universal limit.

Example 2 — Outflow valve opens further

Situation: the controller commands the outflow valve to open further while inflow remains approximately constant.

Reasoning: more air leaves the cabin. Cabin pressure tends to fall, so cabin altitude rises.

Learning point: valve opening increases outflow; it does not directly increase cabin pressure.

Example 3 — Maximum differential reached during climb

Situation: the aircraft climbs above the altitude at which the selected cabin altitude can be maintained within the structural differential limit.

Reasoning: the controller changes to differential-pressure-limited control. Cabin altitude is allowed to rise with aircraft altitude so that ΔP remains within limits.

Learning point: cabin altitude is not necessarily constant throughout cruise.

Example 4 — Slow decompression

Situation: cabin altitude gradually increases during cruise and the outflow valve indication appears abnormal.

Reasoning: possible causes include leakage, inadequate inflow, valve malfunction or controller/sensor fault. Crew must monitor warnings and follow the approved checklist.

Learning point: gradual pressure loss can be less obvious than rapid decompression; instrument monitoring is essential.

Example 5 — Rapid decompression at high altitude

Situation: a loud bang is heard, cabin mist appears and the cabin altitude rises rapidly.

Reasoning: treat the event as a decompression. Flight crew oxygen and emergency descent actions must follow the aircraft's memory items and checklist.

Learning point: immediate oxygen use protects crew performance; diagnosis comes after the immediate safety actions.

Example 6 — Diluter-demand regulator at increasing cabin altitude

Situation: cabin altitude rises while the pilot's regulator is in normal/diluter mode.

Reasoning: the regulator progressively reduces the amount of ambient cabin air mixed with oxygen. At higher cabin altitudes, the mixture becomes richer in oxygen, subject to the regulator's design schedule.

Learning point: diluter-demand systems conserve oxygen at lower altitudes but adapt the mixture as cabin altitude increases.

Example 7 — Smoke reported in the cabin

Situation: smoke is reported and the flight crew oxygen mask is donned.

Reasoning: if the regulator permits cabin-air dilution, contaminated cabin air could enter the mask. The correct 100% oxygen or emergency setting must be selected according to the aircraft procedure.

Learning point: a passenger oxygen mask is not a smoke hood; crew oxygen regulators and PBE have different functions.

Example 8 — Chemical oxygen generator activated

Situation: a passenger pulls a deployed mask and the chemical generator begins operating.

Reasoning: the generator's chemical reaction continues for its designed operating period. The unit becomes hot and cannot normally be switched off or reused.

Learning point: activated chemical generators are one-shot devices and present a heat hazard.

Example 9 — Oxygen cylinder pressure after rapid charging

Situation: a cylinder is charged rapidly and shows a high pressure immediately after servicing.

Reasoning: compression heats the oxygen and cylinder. After cooling, the pressure may fall, revealing that the initial reading was not a stable final indication.

Learning point: oxygen charging must be slow and controlled using approved temperature/pressure procedures.

Example 10 — Negative differential during descent

Situation: outside pressure rises faster than cabin pressure during an abnormal descent profile.

Reasoning: outside pressure may become greater than cabin pressure. A negative-pressure relief valve admits outside air to reduce the inward differential.

Learning point: negative relief protects the pressure vessel from inward loading.

Example 11 — Cabin altitude warning with normal aircraft altitude

Situation: aircraft altitude is stable, but the cabin altitude warning activates.

Reasoning: cabin pressure may be falling because of a leak, outflow valve position, loss of inflow or a control fault. Aircraft altitude alone does not establish that cabin pressure is safe.

Learning point: monitor cabin altitude, rate and differential independently from aircraft altitude.

Example 12 — Oxygen quantity indication and temperature

Situation: oxygen cylinder pressure is lower after the aircraft has been parked in a cold environment.

Reasoning: gas pressure changes with temperature. A lower gauge reading may reflect cooling rather than a proportional loss of oxygen mass, although leakage must never be ruled out without the approved checks.

Learning point: interpret cylinder pressure with temperature and the aircraft maintenance guidance in mind.

Example 13 — Isobaric to differential control transition

Situation: the aircraft continues climbing while cabin altitude initially remains close to the selected value. Later, cabin altitude begins to increase even though the controller remains in automatic mode.

Reasoning: the system may have reached the maximum permitted cabin-to-ambient differential. The controller now allows cabin altitude to rise so the structural limit is not exceeded.

Learning point: a rising cabin altitude during a high-altitude climb is not automatically a fault; compare it with the aircraft's pressure schedule and differential indication.

Example 14 — Outflow valve nearly closed but cabin altitude still rising

Situation: the outflow valve indication shows nearly closed, yet cabin altitude continues to increase.

Reasoning: possible causes include inadequate ECS inflow, excessive fuselage leakage, a pressure-sensing error or a valve indication/control discrepancy.

Learning point: do not diagnose a pressurisation problem from valve position alone. Cross-check cabin altitude, rate, differential, pack status and system messages.

Example 15 — Cabin altitude is steady while aircraft altitude changes slightly

Situation: the aircraft experiences small altitude variations in cruise, but cabin altitude remains almost constant.

Reasoning: the controller is maintaining isobaric cabin control and has sufficient margin before the maximum differential-pressure limit is reached.

Learning point: aircraft altitude and cabin altitude are separate parameters. Their relationship changes with the control schedule.

Example 16 — Cabin pressure does not equalise before landing

Situation: the aircraft is on final approach and the cabin differential remains above zero.

Reasoning: possible causes include incorrect landing elevation selection, controller/valve fault or an abnormal descent profile. Landing with residual pressure can impose unwanted structural loads and affect door operation.

Learning point: use the aircraft-specific indication and checklist. Do not assume that touchdown automatically guarantees zero differential pressure.

Example 17 — Passenger mask has dropped but no oxygen is flowing

Situation: masks are visible in the cabin but a passenger reports no apparent oxygen flow.

Reasoning: depending on system type, mask presentation and oxygen activation may be separate actions. The mask may need to be pulled down to operate a lanyard or valve. A fault or depleted/incorrectly connected supply is also possible.

Learning point: deployment of the mask does not necessarily mean the supply has been activated. Cabin crew instructions and aircraft procedures are essential.

Example 18 — One passenger pulls a mask connected to a shared generator

Situation: one mask in a PSU is pulled down and the generator begins operating.

Reasoning: some chemical generators supply multiple masks. Pulling one mask activates the common generator, which then supplies the masks connected to that unit.

Learning point: one mask pull may activate oxygen for the entire group; the generator is normally a one-shot device.

Example 19 — Oxygen mask is donned but flow indicator does not respond

Situation: the crew member dons the mask but the flow indicator does not show the expected indication.

Reasoning: possible causes include the oxygen supply not being selected, cylinder shut-off/isolation, low supply pressure, disconnected hose, regulator fault or incorrect interpretation of the indicator.

Learning point: verify supply and mask function according to the pre-flight test and QRH. A mask physically covering the face is not proof of oxygen delivery.

Example 20 — Oxygen leak suspected during ground servicing

Situation: a hissing sound or abnormal pressure decay is detected near an oxygen service connection.

Reasoning: oxygen leaks can enrich the local atmosphere and increase fire risk. Personnel must follow the maintenance procedure, isolate the source when safe and avoid ignition sources and incompatible materials.

Learning point: treat oxygen leakage as a serious hazard even though oxygen itself is not a fuel.

Example 21 — Passenger oxygen system versus PBE in a smoke event

Situation: smoke is present and passenger oxygen masks deploy following a cabin pressure event.

Reasoning: passenger masks provide supplementary oxygen but are not designed to filter or exclude smoke. Trained crew may require PBE to protect the eyes and respiratory tract while performing duties.

Learning point: supplementary oxygen and protective breathing equipment solve different problems.

Example 22 — Cabin pressure warning without obvious decompression cues

Situation: the cabin altitude warning activates, but there is no loud noise, fog or passenger reaction.

Reasoning: the event may be a slow decompression or a pressure-control fault. The warning must be treated seriously even without dramatic cues.

Learning point: instrument indications and warnings take priority over the absence of visible symptoms.

Key terms

The essential vocabulary for this chapter. Revise them anytime with the Aircraft General Knowledge flashcards.

Pressurisation
Keeping the cabin at a higher pressure than outside so it feels like a lower altitude.
Cabin altitude
The pressure altitude equivalent to the pressure inside the cabin.
Differential pressure
The difference between cabin pressure and outside air pressure.
Outflow valve
The valve that controls cabin pressure by regulating how much air leaves the cabin.
Safety (positive pressure) relief valve
A valve that opens to prevent excessive differential pressure.
Negative pressure relief valve
A valve that prevents outside pressure exceeding cabin pressure.
Rapid decompression
A sudden loss of cabin pressure, requiring immediate oxygen use and descent.
Chemical oxygen generator
A unit that produces oxygen by a chemical reaction for passenger masks.

19. Summary and revision points

  • Atmospheric pressure and oxygen partial pressure decrease as altitude increases; the oxygen percentage in air remains broadly constant.
  • Hypoxia can impair judgement and performance before the affected person recognises the symptoms.
  • Cabin altitude is the standard-atmosphere altitude equivalent of cabin pressure, not the aircraft's actual altitude.
  • Positive differential pressure means cabin pressure is higher than outside pressure; negative differential means the reverse.
  • Positive-pressure safety valves vent cabin air outward; negative-pressure relief valves admit outside air inward.
  • The outflow valve is the main modulating component in many cabin pressure-control systems.
  • Pneumatic, electro-pneumatic and electronic controllers all aim to achieve a safe cabin pressure schedule.
  • During climb, cabin altitude rises gradually; during cruise it may be held or become differential-limited; during descent it is brought toward landing field pressure.
  • Slow, rapid and explosive decompression differ in how quickly cabin pressure is lost, but all can create serious hypoxia risk.
  • Flight crew oxygen systems commonly use demand or pressure-demand regulators; passenger systems may use continuous-flow gaseous oxygen or chemical generators.
  • Chemical oxygen generators are one-shot devices and become hot during operation.
  • Passenger oxygen masks are not protective breathing equipment and do not protect against smoke.
  • Oxygen supports combustion. Oxygen-system servicing requires strict cleanliness and approved materials.
  • Always use the aircraft-specific AFM/POH, FCOM, QRH and maintenance documentation for limits, modes and procedures.

Final self-check

  • Can you explain why oxygen partial pressure falls even though oxygen remains approximately 21% of the atmosphere?
  • Can you calculate differential pressure from cabin and ambient absolute pressure?
  • Can you explain why the outflow valve normally controls cabin pressure rather than the air inlet?
  • Can you distinguish positive relief from negative relief by direction of airflow?
  • Can you describe what changes when maximum differential pressure is reached?
  • Can you compare continuous-flow, diluter-demand and pressure-demand oxygen?
  • Can you explain why a chemical oxygen generator cannot simply be switched off after activation?
  • Can you distinguish passenger oxygen masks from PBE?
  • Can you explain why rapid charging and oil contamination are dangerous in oxygen systems?
  • Can you state why aircraft-specific QRH/FCOM procedures override generic study notes?
Quick memory aid — pressurisation: ECS supplies air → controller schedules cabin pressure → outflow valve meters discharge → safety valves protect the structure → oxygen equipment protects occupants if cabin pressure becomes inadequate.

17. Knowledge check

Choose the best answer for each question. There are 12 questions. Submit to see your score and explanations.

1. Why does increasing altitude create a hypoxia risk?

2. What does cabin altitude describe?

3. How is positive cabin differential pressure defined?

4. Which component normally regulates cabin pressure by controlling discharged air?

5. What does a positive-pressure safety valve protect against?

6. In which direction does a negative-pressure relief valve permit airflow?

7. What happens when the aircraft reaches the maximum differential-pressure limit during climb?

8. What is the main function of a cabin pressure controller?

9. Following suspected rapid decompression at high altitude, what is the central immediate threat?

10. What distinguishes a diluter-demand oxygen system?

11. Which statement about passenger chemical oxygen generators is correct?

12. Why must oxygen-system components be kept free from oil and grease?

Further study

Use these references to deepen your understanding. Numerical limits, oxygen-use requirements and procedures vary with aircraft certification basis, jurisdiction, operation and aircraft type. The older Airframes and Systems syllabus is used as a topic guide; current regulatory and aircraft-specific sources take precedence for operational decisions.

  1. FAA — Pilot's Handbook of Aeronautical Knowledge: Aircraft Systems and cabin pressurisation.
  2. FAA AC 61-107B — Aircraft Operations at Altitudes Above 25,000 ft MSL or Mach Numbers Greater Than .75.
  3. FAA AC 65-15A — Airframe Handbook: Oxygen systems and aircraft systems.
  4. ASHRAE Handbook — Aircraft: cabin pressure control and relief systems.
  5. FAA — Hypoxia: prevention and treatment information for pilots.
  6. ATSB — A320 pressurisation event, 15 October 2017 (passenger oxygen equipment illustration).
  7. ATSB — Boeing 737 pressurisation event, 6 July 2021 (outflow valve illustration).
  8. Aircraft Systems Tech — Aircraft Oxygen Systems and Components (diluter-demand regulator illustration).
  9. ChemistryViews — Chlorates: Tragic Incidents and Life-Saving Applications, Part 3 (oxygen candle illustration).
  10. Aviation Stack Exchange — Outflow valve mechanical cross-section discussion.
  11. Bombardier — Cabin-pressure control system description (automatic, manual and safety valve operation).
  12. United States 14 CFR — current regulatory text (illustrative jurisdictional reference; not a substitute for applicable Rwanda/EASA/ICAO rules).
AeroLearn learning note: This chapter is original educational material for independent study. It is not a substitute for approved ground school, licensing instruction, aircraft manuals, QRH procedures or maintenance data.

⚑ Spotted a mistake or have a suggestion? Report it here · Terms & disclaimer