AEROLEARN RWANDA/Meteorology/Chapter 6Search·My learning
AeroLearn Rwanda · Meteorology · ATPL foundation

Chapter 6: Humidity

Explore atmospheric water vapour, latent heat, saturation, condensation, humidity measurements, dew point and the Bergeron process — and understand why moisture matters to aviation weather.

Learning outcomes

By the end of this chapter, you should be able to:

6.1 · Fundamentals

1. Water in the atmosphere

Humidity describes the water vapour present in air. Water exists in the atmosphere in three physical states: gas (water vapour), liquid (cloud or fog droplets) and solid (ice crystals or snow crystals). Humidity measurements describe the vapour component, not simply the number of visible cloud droplets.

Water vapour is invisible. A cloud or fog becomes visible when water vapour has changed into tiny liquid droplets, ice crystals, or a mixture of both. The amount of vapour that can coexist with air at saturation depends strongly on temperature: saturation vapour pressure rises as temperature rises.

Do not confuse these

  • Water vapour: gaseous water mixed with air.
  • Cloud droplets: tiny liquid water particles suspended in air.
  • Ice crystals: solid water particles in a cloud.
  • Humidity: a measure of atmospheric water vapour.

Key temperature relationship

At a higher temperature, saturated air has a higher water-vapour capacity than saturated air at a lower temperature. Cooling moist air can therefore bring it to saturation without adding any water vapour.

6.2 · Energy transfer

2. Latent heat

Latent heat is heat absorbed or released when a substance changes state without a change in temperature during the phase change. The energy changes the arrangement and potential energy of the molecules rather than raising or lowering the temperature of the substance while the change is taking place.

For aviation meteorology, the important point is that changes involving atmospheric water redistribute energy. Evaporation absorbs energy from the surroundings; condensation releases energy to the surroundings. This released energy can help sustain rising air and cloud development.

Change of stateEnergy transferAtmospheric meaning
Ice → liquid water (melting)AbsorbedEnergy is required to melt ice.
Liquid water → vapour (evaporation)AbsorbedEnergy is taken from the surface or surrounding air.
Vapour → liquid water (condensation)ReleasedLatent heat is released in cloud or fog formation.
Liquid water → ice (freezing)ReleasedEnergy is released as water freezes.
Vapour → ice (deposition)ReleasedIce forms directly from vapour.
Ice → vapour (sublimation)AbsorbedIce changes directly into vapour.
ICEsolid WATERliquid VAPOURgas Meltingabsorbs Freezing releases Evaporationabsorbs Condensation releases Direct solid ↔ vapour change: sublimation / deposition
Schematic of phase changes. The direction determines whether latent heat is absorbed or released.
Memory aid: Moving towards the vapour state requires energy (evaporation); moving from vapour towards liquid or ice releases energy (condensation or deposition).
6.3 · Water processes

3. Evaporation, saturation and condensation

3.1 Evaporation

Evaporation is the change from liquid water to water vapour. It can occur at temperatures below the boiling point. It requires latent heat, which is absorbed from the water and its surroundings. As evaporation removes energy, the remaining water or nearby surface may cool.

At a given temperature, there is an equilibrium saturation amount. In an open environment evaporation can continue while the air is unsaturated, but the rate also depends on factors such as available water, airflow and the humidity of the air immediately above the surface.

3.2 Saturation

Air is saturated when it contains the maximum water vapour possible at its current temperature and pressure conditions. The chapter explains two routes to saturation:

  1. Add water vapour: evaporation increases the vapour content until saturation is reached.
  2. Cool the air: the saturation capacity decreases as temperature falls; air can reach saturation even if its actual vapour content has not increased.

At saturation, relative humidity is 100%. If saturated air is cooled further, condensation or deposition can occur, provided suitable nuclei and conditions are present.

3.3 Condensation

Condensation is the change from water vapour to liquid water. Latent heat is released. It is the phase change involved in the formation of cloud and fog droplets. Tiny airborne particles called condensation nuclei (including hygroscopic particles) provide surfaces on which droplets can form. The text notes that such particles are usually abundant in the troposphere.

Important distinction: Reaching saturation is a thermodynamic condition; visible cloud or fog requires droplets or ice particles to form and remain suspended in the air. Relative humidity alone does not tell you the visibility.
6.4 · Further phase changes

4. Freezing, melting and sublimation

4.1 Freezing and supercooled water

Freezing is the change from liquid water to ice. It releases latent heat. Freezing generally requires freezing nuclei, which the text describes as less common in the troposphere than condensation nuclei. Consequently, liquid droplets can persist at temperatures below 0°C. These are called supercooled water droplets.

Supercooled droplets are operationally important because they can freeze on contact with an aircraft, producing airframe icing. The detailed aircraft icing hazards are developed later in the meteorology syllabus; here the essential link is that liquid water can exist below freezing.

4.2 Melting

Melting is the change from solid ice to liquid water. Latent heat is absorbed. The chapter notes that there is no equivalent “superfrozen” state in the sense used for supercooled liquid droplets.

4.3 Sublimation and deposition

Sublimation is the direct change between solid ice and water vapour without passing through the liquid state. The term is used for ice → vapour (absorbs latent heat); vapour → ice is more precisely called deposition and releases latent heat. The text also uses “sublimation” for the vapour-to-ice direction and identifies it as deposition.

ProcessDirectionHeat
FreezingLiquid → solidReleased
MeltingSolid → liquidAbsorbed
SublimationSolid → vapourAbsorbed
Deposition (reverse sublimation)Vapour → solidReleased
6.5 · Definitions and units

5. Measures of atmospheric humidity

5.1 Absolute humidity

Absolute humidity is the mass (or weight, in the wording of the text) of water vapour in a unit volume of air. It is normally expressed in grams per cubic metre (g/m³).

Absolute humidity = mass of water vapour / volume of air

5.2 Humidity mixing ratio (HMR)

Humidity Mixing Ratio is the mass of water vapour contained in a unit mass of dry air. It is normally expressed in g/kg. In unsaturated air, the HMR remains constant during ascent in the idealised situation described in the chapter, even though temperature and pressure decrease.

HMR = mass of water vapour / mass of dry air

5.3 Saturation mixing ratio (SMR)

Saturation Mixing Ratio is the maximum amount of water vapour that a unit mass of dry air can contain at a specified temperature. As temperature decreases, the saturation mixing ratio decreases.

5.4 Relative humidity (RH)

Relative humidity compares the actual water vapour content with the maximum amount possible at the same temperature. The chapter expresses it as:

RH = (HMR ÷ SMR) × 100%

In words: relative humidity is the actual water vapour present divided by the saturation amount at that temperature, multiplied by 100.

RHMeaning
100%Saturated air
Below 100%Unsaturated air; described as “dry air” in the chapter’s definition
99.9%Still unsaturated according to the strict definition
Exam trap: “Dry air” in this particular RH definition means RH below 100%; it does not necessarily mean that the air contains no water vapour.

5.5 Example: calculating relative humidity

Suppose a parcel has an HMR of 8 g/kg and, at its current temperature, an SMR of 10 g/kg.

RH = (8 ÷ 10) × 100 = 80%

The parcel is unsaturated. If it is cooled while its actual vapour content remains the same, the SMR falls and RH rises. When HMR equals SMR, RH reaches 100%.

6.6 · Ice-crystal process

6. Bergeron–Findeisen theory

The text calls this the (Wegener)–Bergeron–Findeisen theory. It explains an important process in cold clouds containing both supercooled liquid droplets and ice crystals.

The saturation vapour pressure over liquid water is greater than the saturation vapour pressure over ice at temperatures below 0°C. Therefore, air can be saturated with respect to ice while remaining unsaturated with respect to liquid water. Water vapour tends to deposit onto the ice crystals. As vapour is removed, nearby supercooled droplets evaporate, supplying more vapour. The ice crystals grow while the liquid droplets shrink.

Step-by-step mechanism

  1. A mixed-phase cloud contains supercooled water droplets and ice crystals.
  2. At sub-zero temperatures, saturation vapour pressure over ice is lower than over liquid water.
  3. Water vapour deposits onto ice crystals, so the crystals grow.
  4. Evaporation from supercooled droplets replenishes water vapour.
  5. The droplets diminish while the ice crystals increase in size; the growing ice particles may contribute to precipitation development.
TemperatureRH for water when saturated for iceRH for ice
0°C100%100%
−5°C95%100%
−10°C91%100%
−15°C87%100%
−20°C83%100%

The table reproduces the relationship shown in the chapter: at −10°C, for example, air saturated with respect to ice corresponds to 91% relative humidity with respect to liquid water.

Why it matters: This process is important in the development of precipitation in sub-zero clouds and is also relevant to fog formation. It also helps explain why supercooled droplets may evaporate while ice crystals grow.
6.7 · Observation

7. Measuring humidity: the psychrometer

This course describes two main instrument types: the dry-bulb/wet-bulb hygrometer (psychrometer) and an electrical hygrometer. The psychrometer uses two thermometers exposed to the same air.

7.1 Dry-bulb thermometer

The dry-bulb thermometer measures the ambient air temperature. Its bulb is not covered by a wet wick.

7.2 Wet-bulb thermometer

The wet-bulb thermometer has a muslin wick around its bulb. The other end of the wick is immersed in a reservoir of distilled water. Water moves up the wick and evaporates. Evaporation absorbs latent heat from the bulb, lowering its temperature.

7.3 Wet-bulb depression

The wet-bulb depression is the difference between dry-bulb temperature and wet-bulb temperature.

Wet-bulb depression = T(dry bulb) − T(wet bulb)
DRY BULBWET BULB Ambient air temperatureWet wick + water supplyEvaporationabsorbs heat
Simplified psychrometer principle. The wet wick cools by evaporation; the size of the temperature difference indicates how unsaturated the air is.

7.4 Obtaining humidity values

The dry- and wet-bulb readings are used with psychrometric tables or a slide rule to determine relative humidity, dew point and humidity mixing ratio. Modern systems may use electronic humidity sensors. The chapter identifies an electrical hygrometer as another method.

Key rule: At saturation, dry bulb = wet bulb = dew point. In unsaturated air, dry bulb is normally higher than wet bulb, and wet bulb is normally higher than dew point.
6.8 · Saturation temperature

8. Dew-point temperature

Dew point (DP) is the temperature to which air must be cooled at constant pressure for saturation to occur. If air is cooled to its dew point, its relative humidity reaches 100%. Further cooling can lead to condensation, provided suitable nuclei are present.

Dew point is not the same as wet-bulb temperature, except when the air is saturated. In unsaturated air, the normal relationship is:

Dry-bulb temperature ≥ Wet-bulb temperature ≥ Dew-point temperature

At saturation all three are equal. The chapter gives a dew-point lapse rate of approximately 0.5°C per 1000 ft. Treat this as the chapter's stated training value, not as a universal fixed rate for every atmospheric situation.

Worked example

Air has a dry-bulb temperature of 24°C and a dew point of 18°C. The dew-point spread is:

24°C − 18°C = 6°C

The air must cool by 6°C at constant pressure to reach saturation. A smaller temperature/dew-point spread generally indicates air is closer to saturation, although actual fog or cloud formation also depends on lifting, mixing, nuclei and local conditions.

Operational interpretation: A small temperature–dew-point spread is a useful signal to monitor for possible mist, fog or low cloud when the air cools or is lifted. It is not, by itself, a guarantee that fog will form.
6.9 · Daily cycle

9. Diurnal variation of relative humidity

Relative humidity commonly changes through the day even if the actual amount of water vapour changes little. The reason is that the saturation amount depends on temperature.

HighLowLocal time →0006121824 Relative humidityAir temperatureSchematic only — not measured values
Typical inverse daily pattern: temperature rises as RH falls, then temperature falls as RH rises, assuming moisture content changes little.

The chapter notes that higher RH at night helps explain why mist and fog can form after dark, particularly in autumn and winter. It identifies the maximum RH as approximately 30 minutes after sunrise, when temperature is at its minimum.

Important assumption: The simple inverse relationship assumes that the actual water-vapour content remains roughly constant. Advection, evaporation, precipitation, mixing and changing air masses can alter moisture content, so real observations may differ.
6.10 · Operational relevance

10. Why humidity matters in aviation

10.1 Fog, mist and visibility

When air near the surface reaches saturation and droplets form, visibility may be reduced. A small temperature–dew-point spread, light winds and nocturnal cooling can be useful clues during weather assessment. The actual formation and persistence of fog also depend on wind, cloud cover, terrain, moisture supply and local temperature structure.

10.2 Cloud and precipitation

Condensation releases latent heat. In rising saturated air, that energy affects the rate of cooling and the development of clouds. In cold clouds, the Bergeron process can contribute to ice-crystal growth and precipitation.

10.3 Aircraft icing

Supercooled liquid droplets can exist below 0°C. If they strike an aircraft and freeze, they can produce airframe icing. A forecast or report of sub-zero cloud does not automatically mean all cloud water is ice; liquid supercooled droplets may be present.

10.4 Weather observation and dispatch awareness

Humidity data help interpret the likelihood of fog or low cloud and provide context for temperature trends. Flight operations personnel should assess humidity alongside temperature, dew point, wind, cloud, visibility, runway conditions, METARs, TAFs, SIGMETs and relevant local reports. Humidity alone is not a substitute for the full operational weather picture.

Mini operational scenario

A station reports a temperature of 17°C and dew point of 16°C shortly before sunrise. The 1°C spread indicates air close to saturation. If the surface cools slightly further and winds remain light, fog or mist may become a concern. A dispatcher should monitor updated observations and visibility trends rather than assume fog is certain.

Extended explanation · Additional depth

13. A deeper look at water vapour and saturation

13.1 Water vapour is invisible

Water vapour is water in its gaseous state and is normally invisible. The white plume seen above a boiling kettle is not the invisible vapour itself; it consists mainly of tiny liquid droplets that formed after the hot moist air mixed with cooler surrounding air. The same distinction matters in aviation meteorology: cloud and fog are visible because liquid droplets or ice crystals scatter light, whereas the water vapour between those particles cannot normally be seen.

Water molecules do not become a different substance when water changes state. The molecules remain H2O; what changes is their energy and how they move and interact. In ice, molecules occupy an ordered structure; in liquid water they move around one another; in vapour they are much farther apart and move freely.

13.2 Why temperature changes relative humidity

Relative humidity is a ratio, not a direct measure of the total water vapour in the air. The numerator is the actual vapour content; the denominator is the saturation amount at the current temperature. If the actual vapour content remains unchanged while the air warms, the saturation amount increases and the ratio becomes smaller. If the air cools, the saturation amount decreases and the ratio becomes larger.

Worked example — same moisture, different temperature

Imagine a parcel contains 6 g/kg of water vapour. At its first temperature, the saturation mixing ratio is 12 g/kg:

RH = (6 ÷ 12) × 100 = 50%

The parcel cools but does not gain or lose vapour. At the lower temperature, suppose the SMR is now 8 g/kg:

RH = (6 ÷ 8) × 100 = 75%

The amount of vapour has not changed, but RH has risen from 50% to 75% because the air is closer to saturation.

13.3 Saturation is not the same as “full of water”

Air is not a sponge with a fixed capacity. The saturation amount depends on temperature, and the phrase “air can hold water” is a useful teaching shorthand. More precisely, saturation is the equilibrium condition between water vapour and a condensed water surface at a given temperature. The warmer the air, the higher the saturation vapour pressure and the greater the saturation mixing ratio.

Extended explanation · Energy and phase change

14. Latent heat in more detail

14.1 Latent heat versus sensible heat

Sensible heat changes the temperature of a substance. Latent heat is associated with a change of state. For example, warming liquid water from 10°C to 20°C changes its temperature: this is sensible heating. Evaporating some of that water requires energy even if the temperature of the remaining liquid does not change during the phase transition: this is latent heat absorption.

During condensation, water vapour changes to liquid and releases latent heat. This does not mean a cloud is automatically warm or that its temperature must rise without limit. It means the phase change transfers energy to the surrounding air, influencing the parcel's thermal behaviour.

14.2 Why evaporation cools

Evaporation requires energy for molecules to escape the liquid into the vapour state. That energy is drawn from the liquid and nearby surroundings. This is why wet skin feels cool when water evaporates, and why the wet-bulb thermometer reads below the dry bulb in unsaturated air. The rate of evaporation is affected by the vapour-pressure difference between the wet surface and the surrounding air, as well as ventilation and available water.

14.3 Why condensation matters to cloud development

When moist air rises and cools to saturation, water vapour can condense onto suitable nuclei. The condensation releases latent heat into the air parcel. In a rising saturated parcel this release partly offsets the cooling caused by expansion. The detailed rates of cooling in saturated and unsaturated rising air are treated in the next chapter, Adiabatics and Stability; here the essential humidity link is the release of latent heat during condensation.

Do not mix up the chapters: Chapter 6 explains the moisture and phase-change processes. Chapter 7 develops the temperature changes of rising and sinking air, including dry and saturated adiabatic lapse rates.
Extended explanation · Calculations

15. Comparing humidity measures

MeasureWhat it compares or describesTypical unitWhat to remember
Absolute humidityWater-vapour mass in a volume of airg/m³Depends on the volume used; temperature and pressure changes can affect the volume.
HMRWater-vapour mass per mass of dry airg/kgUseful for tracking moisture content of an unsaturated parcel.
SMRMaximum vapour mass per mass of dry air at a specified temperatureg/kgFalls as temperature falls.
RHActual vapour content as a percentage of the saturation amount%Changes when temperature changes, even if actual vapour content stays the same.
Dew pointTemperature at which air becomes saturated when cooled at constant pressure°CClose to air temperature means the air is close to saturation.
Wet-bulb temperatureTemperature reached through evaporative cooling of a wetted thermometer°CApproaches dry-bulb temperature as RH approaches 100%.

15.1 Worked example — calculate HMR from RH and SMR

At a given temperature, the SMR is 14 g/kg and the relative humidity is 60%. Rearrange the RH formula:

HMR = (RH ÷ 100) × SMR
HMR = 0.60 × 14 = 8.4 g/kg

The actual humidity mixing ratio is 8.4 g/kg. The parcel is unsaturated because HMR is less than SMR.

15.2 Worked example — find RH after cooling

A parcel has an HMR of 7 g/kg. At its original temperature the SMR is 10 g/kg, so RH is 70%. After cooling, the SMR falls to 7.5 g/kg:

RH = (7 ÷ 7.5) × 100 = 93.3%

The parcel is now close to saturation. Only a small additional reduction in saturation capacity would be required to reach 100%, assuming no moisture is added or removed.

15.3 Worked example — identify saturation

Parcel A has HMR 9 g/kg and SMR 9 g/kg. Its RH is 100%, so it is saturated. Parcel B has HMR 9 g/kg and SMR 12 g/kg. Its RH is 75%, so it is unsaturated. Both parcels contain the same HMR, but their relative humidities differ because their saturation limits differ.

15.4 Worked example — wet-bulb depression

A psychrometer records a dry-bulb temperature of 26°C and a wet-bulb temperature of 20°C:

Wet-bulb depression = 26 − 20 = 6°C

The 6°C depression indicates appreciable evaporative cooling and therefore unsaturated air. The exact RH, dew point and HMR must be obtained from the appropriate psychrometric table or instrument calculation; do not estimate an exact RH from the depression alone without the required table or formula.

15.5 Worked example — dew-point spread

At an aerodrome the temperature is 19°C and the dew point is 17°C. The spread is 2°C. If the air cools by approximately 2°C at constant pressure without a significant moisture change, it will reach saturation. This is a useful reason to monitor visibility and cloud base trends, but it does not prove fog will form.

Extended explanation · Instrument use

16. Reading and interpreting a psychrometer

16.1 Why the wet bulb is cooler

The muslin wick supplies a thin film of water to the wet-bulb thermometer. Some of that water evaporates into the surrounding air. Evaporation requires latent heat, which is drawn from the bulb and wick, so the wet-bulb temperature falls. The thermometer stabilises when energy transfer to the wet bulb balances the cooling associated with evaporation.

16.2 What controls the wet-bulb depression?

16.3 Interpreting the three temperatures

Air conditionDry bulbWet bulbDew point
SaturatedEqualEqualEqual
UnsaturatedHighestBetween dry bulb and dew pointLowest

For example, a dry bulb of 22°C, wet bulb of 18°C and dew point of 15°C is a physically consistent unsaturated reading pattern. The values show that the air is not saturated, but an exact RH should be obtained from a psychrometric table or calculator.

16.4 Electrical hygrometers

The chapter also identifies electrical hygrometers. Modern electronic humidity sensors commonly use an electrical property that changes with moisture content; the instrument's electronics convert the sensor response into a humidity value or dew point. The Met Office describes capacitive sensors as one example of modern measurement technology. These devices complement, rather than change, the underlying humidity definitions.

Extended explanation · Applied meteorology

17. Aviation case studies and operational examples

17.1 Early-morning fog watch

Situation: An aerodrome reports 12°C with a dew point of 11°C at 0430 local time. The wind is light and the sky is mostly clear.

Reasoning: The 1°C spread means the air is close to saturation. With light wind and continued surface cooling, the temperature may fall to the dew point. Fog is a possibility, not a certainty; local moisture, terrain, cloud cover and any change in wind or air mass will affect the outcome.

Operational response: Monitor successive METARs, visibility, temperature/dew-point spread and TAF amendments. Consider the effect of reduced visibility on departure sequencing, approach minima, alternates and fuel planning according to company procedures.

17.2 A warm afternoon with lower RH

Situation: At 0800 the air temperature is 18°C and RH is 85%. By 1400 the temperature has risen to 27°C. Assume the actual moisture content changes very little.

Reasoning: The warmer air has a higher saturation mixing ratio. The RH will generally fall even though the air has not necessarily lost much water vapour. A lower afternoon RH does not by itself mean that the air mass has become substantially drier.

17.3 Supercooled droplets on approach

Situation: An aircraft is expected to descend through cloud with reported temperatures below 0°C.

Reasoning: The presence of sub-zero cloud does not establish whether the cloud contains ice crystals, supercooled liquid droplets, or both. Supercooled droplets can freeze on aircraft surfaces on impact.

Operational response: Use approved icing forecasts, SIGMETs, PIREPs and aircraft procedures. Humidity theory explains why liquid droplets can persist below 0°C; it does not replace aircraft-specific icing limitations or operational guidance.

17.4 Moisture changes during ascent

Situation: An unsaturated parcel rises. Before saturation, it cools as pressure decreases, but in the idealised treatment its HMR remains constant.

Reasoning: As the parcel cools, its SMR decreases. Since HMR stays constant while SMR falls, RH increases. If the parcel reaches the point where HMR equals SMR, it becomes saturated. The next chapter explains the adiabatic temperature changes and stability framework needed to analyse this ascent in more detail.

17.5 Fog is not guaranteed by 100% RH at a distant station

A station may report saturated air while an adjacent runway remains clear, because saturation can occur in a shallow layer or at a different height or location. Visibility depends on the distribution and concentration of droplets along the runway and approach path. Always use aerodrome observations and forecasts rather than extrapolating a single humidity value across a large area.

Dispatcher's checklist: Compare temperature and dew point; examine the trend over successive reports; check wind speed/direction and cloud cover; review visibility and cloud base; consider terrain and local fog climatology; then apply the relevant operational minima and company procedures.

11. Chapter summary

Glossary

TermDefinition
HumidityWater vapour content of air.
Latent heatEnergy absorbed or released during a change of state without a temperature change during the transition.
EvaporationLiquid water changing to vapour; absorbs latent heat.
SaturationAir containing the maximum water vapour possible at its temperature.
CondensationWater vapour changing to liquid; releases latent heat.
Supercooled dropletLiquid water droplet at a temperature below 0°C.
Absolute humidityMass of water vapour per unit volume of air.
HMRMass of water vapour per unit mass of dry air.
SMRMaximum vapour mass per unit mass of dry air at a specified temperature.
Relative humidityActual vapour content as a percentage of the saturation amount.
PsychrometerHumidity instrument using dry- and wet-bulb thermometers.
Wet-bulb depressionDry-bulb temperature minus wet-bulb temperature.
Dew pointTemperature to which air must be cooled at constant pressure to reach saturation.
DepositionWater vapour changing directly to ice.
Bergeron processIce-crystal growth in mixed-phase clouds at the expense of supercooled droplets.

12. Knowledge check — 20 MCQs

Select one answer for each question, then check your result. Each question includes an explanation.

Further study

External images require an internet connection. Educational material for study; always use current official meteorological products and operational procedures for real flight decisions.

⚑ Spotted a mistake or have a suggestion? Report it here · Terms & disclaimer